Hi, this is Archer72, for another episode of Hacker Public Radio.
In this episode, I try to head down memory lane in my experience or lack of it.
This need to recall my memories was in part from a comment by Whiskeyjack on Robots and Industrial drives.
While I don’t have direct experience with robotics, this was an interesting enough field to explore based on my limited knowledge. I won’t mention robotics, with the exception of a one year stint at a workplace called Fanuc. This location in Illinois dealt with the drives that may have powered the robots that the company featured, but I have no direct interfacing with these machines.
The area of work that I seem to have been drawn to several times is the one repairing industrial spindles, servos and power supplies. Also there is a phantom memory of a company that used VFD’s or Variable Frequency Drives to power some fountains in Las Vegas. I did a little digging into my history of social security payments to try and recall this area of work, as I am in the United States, and the government keeps records back to my first job 35 years ago.
United States Social Security History
Sign in with ID.me > Go to Home > Review your full earnings
record now > Click to close Privacy Act Statement > Not sure if
you need to request a correction?
>
View Details
on
Every Single Entry
, no nicely
compiled list.
I should back up and explain a few things. Some types of industrial equipment that I have some experience in can be related to something more familiar.
In a 480 VAC industrial power supply, the incoming three-phase 480 VAC is first rectified to a nominal DC bus voltage of about 650–680 VDC. The electrical conversion from AC to DC is performed by feeding the AC through a set of three I.G.B.T modules, one for each phase of AC. DC-link capacitors then smooth the rectified voltage with and electrolytic capacitor, usually ranging from 2000 µF to 4000 µF depending on the specific requirements of the system
I.G.B.T is short for
Insulated
gate bipolar transistor
, and is the building block of industrial
drives.
This applies not only to PSM (Power Supply Modules), but are part of
Spindle and Servo amplifiers.
The first time I repaired spindles in the workforce was a year long job in 2010. The spindle drives that we repaired did not have great quality parts, that were sourced as used parts on Ebay. The drives that we repaired were for the Yaskawa company headquartered in Japan.
The only repair that is memorable there was when I traced the drive not powering up to a burnt signal trace leading to the microprocessor.
The second time doing this type of job was in 2022 with
Fanuc
, this time for another
year with spindle drives, servo amplifier and related power
supplies.
Most of the units were supplied with 480 volts, while on the low voltage
benches they were 240 volts.
There were a couple of times that the 3 phase power leads, labeled as R, S and T were reversed leading to the power supply. This caused the inrush resistor to do it’s designated job and blow out in a similar way to a fuse. This part is made of a ceramic outer layer and a sandy type inner layer, which is a mess with overcurrent.
The other type of catastrophic failure that I would see frequently before powering up the on the bench was that the I.G.B.T. modules were blown out due to the excess regenerative braking voltage feeding back in these type of power transistors.
Overvoltage conditions can arise from:
Regeneration:
When a motor decelerates rapidly, it can send energy back into the drive, increasing the DC bus voltage.
Transient Events:
Lightning strikes, utility switching, or large motor starts can cause instantaneous voltage spikes.
There were a few times that the IGBT’s were blown out with enough force to expose the gel that was insulating the part.
During the time at this company, there was a trade show demostrating the Robotics side of the business. The Fanuc M-2000iA robot was shown lifting and maneuvering a Corvette.
CC Attribution to : CNC Control panel : 3d model
Additional resources:
Fanuc AC Servo & Spindle Motor, and Servo Amplifier Manuals by Fanuc LTD
Fanuc Series 30i (and others) CNC Controller Manual Collection by Fanuc LTD
I couldn’t find a photo of catastrophic failure for this module, but you can see how this could make quite a mess!!
Iwaki 0381/A Resistor module 10 ohms